Réhabilitation de l’Ehpad Saint Antoine à Tournon-sur-Rhône (07)

Refurbishment of Saint Antoine nursing home in Tournon-sur-Rhône (07)

  • ROUX CABRERO
  • Santé

The refurbishment of Saint Antoine nursing home in Tournon-sur-Rhône involves the restructuring and extension of a building dating from the 1980s, with a capacity of 144 beds. Entrusted to Roux Cabrero, a Fayat Bâtiment subsidiary, this structural works project combines demolition, reconstruction and major refurbishment works, while incorporating high-performance and environmentally responsible technical solutions.

A complex restructuring and extension project

The project aims to restructure and extend the nursing home while maintaining its existing accommodation capacity. The client is Tournon-sur-Rhône Hospital, supported by A2MO as project management consultant, while the design and engineering services are provided by CHABANNE ARCHI//INGE. The project is characterised by a carefully planned swing-space phasing strategy, spread over 47 months, to combine major construction works with the partial retention of existing structures.

Réhabilitation de l’Ehpad Saint Antoine à Tournon-sur-Rhône (07) 2

The works are being carried out in three successive phases. The first phase involves the construction of new accommodation wings over a 21-month period, comprising four-storey buildings (ground floor plus three upper floors) supported by deep foundations. The second phase, lasting 16 months, includes the partial demolition of two existing wings and the reconstruction of a new four-storey section, requiring particular attention to the structural stability of the retained buildings. Finally, the third phase, lasting 10 months, focuses on the restructuring and refurbishment of two existing wings, excluding the ground floor, as well as the redevelopment of the outdoor spaces.

Réhabilitation de l’Ehpad Saint Antoine à Tournon-sur-Rhône (07) 3

A construction project incorporating environmental performance objectives

The project addresses major environmental challenges, with the aim of reducing its carbon footprint and improving the building's energy efficiency. In accordance with E3C1 environmental performance standards and RT 2012 regulations, Roux Cabrero has prioritised the use of low-carbon concrete throughout the structural works. This approach helps reduce construction-related carbon emissions while ensuring the long-term durability of the structures and the thermal performance of the refurbished spaces.